Side-Power SEP 100/185 T Manual de Serviço Página 228

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 284
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 227
Section 918
EI MVP-50P
918 - 4 Page Date: 29. September 2014
Pilot´s Operating Handbook
EXTRA 330LX
FUEL PRESSURE INDICATOR
green range 0 psig - 14 psig
red line 14 psig
918.3 EMERGENCY PROCEDURES
Not affected.
918.4 NORMAL PROCEDURES
Magneto Check
- Check the magnetos at 1800 RPM. Allowed drop is 175 RPM
(max. difference 50 RPM).
- Check Alternator Output.
- Move also the propeller control through its complete range to check operation and
return to full "HIGH RPM" position.
Turn boost pump "ON" (check indicator movement on the fuel flow gauge).
During engine start:
MVP-50P ON
918.5 PERFORMANCE
Not affected.
Vista de página 227
1 2 ... 223 224 225 226 227 228 229 230 231 232 233 ... 283 284

Comentários a estes Manuais

Sem comentários